Electric Wire Flame Test Chamber 1000Ml / M Flow Range For Finished Wire / Cord
Scope:
Applicable to finished wire or cord in the specified conditions to inhibit the spread of flame has the ability, and its use of the cable: that is, power, communication and so on.
Main Components:
1, ignition control system
2, the collection tower and smoke devices
3, gas flow control system
4, temperature control system
5, the extension of the combustion control system
6, horizontal and vertical burning stent
Main Specifications:
1, the combustion chamber: 4m³ volume of stainless steel wall, equipped with tempered glass windows, exhaust fan, foot switch.
2, burner: standard test flame has a nominal height of 125mm, the following 500w (1700Btu / h) standard speed heat release.
3, temperature control system: A: K-type thermocouple, with a diameter of 0.5mm stainless steel to do the jacket.
4. The diameter of the mouth: 0.90 ± 0.03mm, nozzle length: 1.60 ± 0.05mm. B: Thermometer and K-type thermocouple match, the reading of up to 800 ¡æ or more.
5, high-precision flame control system: the flame burning time through the optical control system to measure the flame burning time, timing device 0 ~ 999.9s
6, flow meters, pressure gauges, pressure relief valve:
A, fluid pressure gauge / pressure gauge Measuring 800mm water, and 5mm increments
B, flowmeter rotor test table in accordance with the D3195 standard calibration. And a gas table, or with a precision of at least 2% of the flow table. Flow range: 1000ml / M.
C, gas relief valve: 1, the gas flow can be adjusted to 10 pounds per cubic inch.